Core identification
		
				Colour
		
	 
	
	
	
	
	
	
		Colour outer sheath
		
				Orange
		
	 
	
	
		Diameter conductor (mm)
		
				0.58
		
	 
	
		Conductor material
		
				Copper
		
	 
	
		Screen over stranding element
		
				Foil
		
	 
	
		Screen over stranding
		
				Braiding
		
	 
	
		Material outer sheath
		
				Polyolefin
		
	 
	
		Characteristic impedance (Ohm)
		
				100
		
	 
	
		Conductor category
		
				Class 1 = solid
		
	 
	
		Armouring/reinforcement
		
				None
		
	 
	
		Permitted cable outer temperature during assembling/handling (°C)
		
				0 - 50
		
	 
	
		Permitted cable outer temperature after assembling without vibration (°C)
		
				-20 - 60
		
	 
	
		Number of stranding elements
		
				4
		
	 
	
	
	
		Suitable for underground installation
		
				No
		
	 
	
		Halogen free according to EN IEC 60754-2
		
				Yes
		
	 
	
		Insulation integrity according to IEC 60331
		
				No
		
	 
	
		Low smoke according to EN IEC 61034-2
		
				No
		
	 
	
	
		Outer diameter approximate (mm)
		
				7.5
		
	 
	
		With rodent protection
		
				false
		
	 
	
		Low smoke (according to EN 61034-2)
		
				No
		
	 
	
	
		Halogen free according to EN 60754-1/2
		
				Yes
		
	 
	
		Oil resistant (according to IEC 60811-404)
		
				No
		
	 
	
	
		Longitudinal water blocking cable
		
				false
		
	 
	
		Radial water blocking cable
		
				false
		
	 
	
		Reaction-to-fire according to EN 13501-6: Class
		
				Cca
		
	 
	
		Reaction-to-fire according to EN 13501-6: Smoke production
		
				s1
		
	 
	
		Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
		
				d1
		
	 
	
		Reaction-to-fire according to EN 13501-6: Acidity
		
				a1
		
	 
	
	
		Min. permitted bending radius, moving application with forced guidance (mm)
		
				0
		
	 
	
		Min. permitted bending radius, moving application/free movement (mm)
		
				0
		
	 
	
		Min. permitted bending radius, stationary application/permanent installation (mm)
		
				30
		
	 
	
		Specification material outer sheath
		
				Other
		
	 
	
	
		Core identification according to HD 308 S2
		
				No
		
	 
	
		Suitable as telephone cable
		
				Yes
		
	 
	
		Suitable as computer data cable
		
				Yes
		
	 
	
		Suitable as signalling cable
		
				Yes
		
	 
	
		Certified for shipboard application
		
				No
		
	 
	
		Max. tensile strength during installation (kN)
		
				0.18
		
	 
	
		Approved type of underground installation
		
				Underground installation tube